Low-voltage dry-type capacitor is used the most advanced all-metal polypropylene film as raw material, introducing foreign advanced technology Technique and equipment production accordance with national standards IEC in strict , mainly for low-voltage power grid to improve power factor, reduce reactive loss and improve power quality.
Main features:
(1)Self-healing
excellent self-healing properties, using the most advanced
full-metal polypropylene film as the medium, if the medium be
damaged, the metal electrode around this damage points in an
instant incurs volatile disappear, and immediate resumption of
insulation, so that the capacitor recover and continue normal
operation.
(2) low loss
The actual value less than 0.1%, so the capacitor has low energy
consumption, less heat, low temperature, long life , good of energy
saving.
(3) security
In line with GB, IEC standard, protection devices installed in a
single-capacitor attached to the internal; when an exception occurs
in a circuit or single-capacitor , the protection device will be an
immediate action, automatically cut off power to prevent a
secondary disaster. Attached to the discharge resistor, to ensure
safety of electricity and maintenance . Shell made of pressed
steel, painted lacquer baked high temperature inside and outside
which has good weather resistance ability, so it has high security.
(4 )convenience
Small size and light weight, easy to install and carry
Technical parameters
Standard: GB12747-1 (2004) IEC60831-1 (1996/2002) IEC60831-2
(1995).
Form: dry self-healing
Ambient temperature: house type, the working environment
temperature -25~ +50 ℃, humidity95%, altitudeRated voltage:
230,260,440,480,525,660,690 V (voltage levels according to demand
can up to 1000V)
Rated capacity: 10 ~ 100KVAR
Capacity error: -5% to +10%.
Allow over-voltage: below 110% of rated voltage (intermittent use).
Allow over-current: below 130% of rated current.
Dielectric loss: 0.2W/Kvar below.
Discharge characteristics: built-in discharge resistors, residual
voltage drops below 50V in 1 minute when capacitors cut off power .
Filling: smothering stone (with fire-proof, explosion-proof,
pressure-proof functions)
Appearance: Square
Degree of protection: IP 42
Selection Table: 150HZ 250V applied phase compensation
| Capacitor Type | Capacitor model | Phase capacity | Phase current | Each output capacity | Capacitor size | Appearance | |||
| A | B | C | D | ||||||
| 250V 15Kvar | DNSC/15-250-1P | 5 Kvar | 20A | 220V 4Kvar | 200 | 75 | 250 | 310 | Figure 2 |
| 250V 30Kvar | DNSC/30-250-1P | 10 Kvar | 40A | 220V 8Kvar | 230 | 130 | 250 | 310 | |
| 250V 45Kvar | DNSC/45-250-1P | 15 Kvar | 60A | 220V 12Kvar | 230 | 130 | 250 | 310 | |
three single-phase composition | |||||||||
Selection Table: 350HZ 260V 220V system voltage applied
| Capacitor Type | Capacitor model | Current(A) | Each output capacity | Capacitor size | Appearance | |||
| A | B | C | D | |||||
| 260V 10Kvar | DNSC/10-260-3P | 22.2 | 220V 7Kvar | 200 | 75 | 250 | 310 | Figure 2 |
| 260V 15Kvar | DNSC/15-260-3P | 33.3 | 220V 11Kvar | 230 | 130 | 250 | 310 | |
| 260V 20Kvar | DNSC/20-260-3P | 44.4 | 220V 14Kvar | 230 | 130 | 250 | 310 | |
| 260V 25Kvar | DNSC/25-260-3P | 55.5 | 220V 18Kvar | 230 | 185 | 250 | 310 | |
| 260V 30Kvar | DNSC/30-260-3P | 66.6 | 220V 21Kvar | 230 | 185 | 250 | 310 | |
| 260V 35Kvar | DNSC/35-260-3P | 77.7 | 220V 25Kvar | 350 | 140 | 370 | 430 | |
350HZ 480V 400V system voltage applied
| Capacitor Type | Capacitor model | Current(A) | Each output capacity | Capacitor size | Appearance | |||
| A | B | C | D | |||||
| 480V 10Kvar | DNSC/10-480-3P | 12.0 | 400V 7Kvar | 200 | 75 | 250 | 310 | Figure 1 |
| 480V 20Kvar | DNSC/20-480-3P | 24.1 | 400V 14Kvar | 220 | 140 | 250 | 310 | |
| 480V 30Kvar | DNSC/30-480-3P | 36.1 | 400V 22Kvar | 220 | 140 | 250 | 310 | |
| 480V 40Kvar | DNSC/40-480-3P | 48.1 | 400V 30Kvar | 350 | 140 | 250 | 310 | |
| 480V 50Kvar | DNSC/50-480-3P | 60.1 | 400V 37Kvar | 350 | 140 | 370 | 430 | |
| 480V 60Kvar | DNSC/60-480-3P | 72.2 | 400V 44Kvar | 350 | 140 | 370 | 430 | |
| 480V 70Kvar | DNSC/70-480-3P | 84.2 | 400V 52Kvar | 350 | 140 | 470 | 530 | |
| 480V 80Kvar | DNSC/80-480-3P | 96.2 | 400V 59Kvar | 350 | 140 | 470 | 530 | |
| 480V 90Kvar | DNSC/90-480-3P | 108.3 | 400V 66Kvar | 350 | 140 | 470 | 530 | |
| 480V 100Kvar | DNSC/100-480-3P | 120.3 | 400V 74Kvar | 350 | 140 | 470 | 530 | |
350HZ 525V 400V system voltage applied
| Capacitor Type | Capacitor model | Current(A) | Each output capacity | Capacitor size | Appearance | |||
| A | B | C | D | |||||
| 525V 10Kvar | DNSC/10-525-3P | 11.0 | 400V 6Kvar | 200 | 75 | 250 | 310 | Figure 1 |
| 525V 20Kvar | DNSC/20-525-3P | 22.0 | 400V 12Kvar | 220 | 140 | 250 | 310 | |
| 525V 30Kvar | DNSC/30-525-3P | 33.0 | 400V 17Kvar | 220 | 140 | 250 | 310 | |
| 525V 40Kvar | DNSC/40-525-3P | 44.0 | 400V 23Kvar | 350 | 140 | 250 | 310 | |
| 525V 50Kvar | DNSC/50-525-3P | 55.0 | 400V 29Kvar | 350 | 140 | 370 | 430 | |
| 525V 60Kvar | DNSC/60-525-3P | 66.0 | 400V 35Kvar | 350 | 140 | 370 | 430 | |
| 525V 60Kvar | DNSC/70-525-3P | 77.0 | 400V 41Kvar | 350 | 140 | 470 | 530 | |
| 525V 80Kvar | DNSC/80-525-3P | 88.0 | 400V 46Kvar | 350 | 140 | 470 | 530 | |
| 525V 90Kvar | DNSC/90-525-3P | 99.0 | 400V 52Kvar | 350 | 140 | 470 | 530 | |
| 525V 100Kvar | DNSC/100-525-3P | 110.0 | 400V 58Kvar | 350 | 140 | 470 | 530 | |
Applications
1, the modern industry: the petrochemical industry, automobile manufacturing industry, steel industry and semiconductor industry, communication industry, paper light industry, tobacco industry
2, civil construction: commercial office buildings, medical hospitals, stadiums, exhibition halls, hotels, airport terminals, schools
Custom labeled correctly
1, the capacitor with the number of rated capacity, output capacity, rated voltage of the capacitor.
2, phases number of reactor , the series reactance factor.
If you want to buy or for more information, please contact us

Technical parameters: System voltage: 220 ~ 750V Rated Capacity: 120 ~ 450KVAR / cabinet Resonant frequency: 130Hz, 141Hz, 189Hz, 204Hz other ...
Features: 1 tuning filter cabinet is designed to compensate to the power grid generated harmonics for power factor 2 each section of the filter tuning ...
Load control tunable filter: 1 high-power devices with fast load changes, such as welding machines, will cause the voltage drop of distribution ...
Main purpose and scope of application DNDT series of dynamic reactive power compensation switching regulator is a new low-voltage reactive power ...
Transmission and distribution system is running on a sine wave voltage and current waveforms with fixed-frequency . However, non-linear loads , like: ...
Transmission and distribution system is running on a sine wave voltage and current waveforms with fixed-frequency . However, non-linear loads , like: ...